KYL-816

KYL-816

Features

 

KYL-816 Analog Wireless Acquisition Module has the function for analog acquisition and wireless transmission, do not re-empolder,it can achieve the function for wireless remote controlling and collecting data with a low cost. It is industrial design and has a wide work temperature so that can meet client’s requirement for whole day using. Besides, the RF adopts narrowband FM and has high anti-jamming. Accord with EN300220.


       

Features

 

1、Analog: two channels 0-5V voltage/4-20mA current input and two channels 0-5V voltage/4-20mA current output.

2、Power supply: 12-30V, providing protection for power supply in reverse.

3. There are power monitor circuit and watch dog circuit for the CPU, and ensure that this module can operate at adverse circumstances.

4、With the indicator light of power supply, operation, receive and transmit.

5、Wireless communication interrupt alarm output. 1) Relay alarm output 2) Voltage/current output 0

6、Can work by Modubus RTU protocol.

  

Technical specification 
                                                                   
                                        KYL-816 Parameters

FeaturesRangeRemark
Power supply D.C.24V12-30V Output current≥500mA
Transmission distance1-3 KM Line-of-sight
Ourput No. 2個(gè) 
Output typeVoltage(0-5V)Or Current(0-20mA)Specified before shipment
Input No. Can be extended to 4
Input typeVoltage(0-5V)Or Current(0-20mA)Specified before shipment
Conversion accuracy0.50%12BIT ADC
Relay alarm outputDry ContactMaximum load capacity 30V/1A
Transmitting Current 300mA-
Receiving Current30mA-
Frequency433MHz 
ModulationFSK 
Dimension138mm*90mm*40mm-

 KYL-816 Interface description

80604.jpg

 The Function-indicator light

1、Indicator light for the power supply(PWR):power supply indication;

2、Indicator light for working(RUN):indication for the equipment working in gear, the bicker period is 2S when the equipment work in gear. 

3、Indicator light for transmit(TX):indication for data transmitting.

4、Indicator light for receive(RX):indication for data receiving.



Two-wire current sensor and KYL-816 connection

                                         Connection diagram

 

80605.jpg

Pin Definitions 

 

                                     KYL-816 Pin Definitions

  

Pin no.FeturesRemarks Remarks 
1VCC power inputDC:10-30V 
2GNDGrounding of power supply 
3Relay passive output(ERR)Wireless communication signal interrupt alarm outputMaximum load capacity 30V/1A
4
5--  
6GNDSignal ground 
7--  
8GNDSignal ground 
9Current output IO2+The second current output positive terminal 
10GNDSignal ground 
11Current output IO2-The second current output negative terminal 
12GNDSignal ground 
13Current output IO1+The first current output positive terminal 
14GNDSignal ground 
15Current output IO1-The first current output negative terminal 
16GNDSignal ground 


Using Method 

 

1、Master-slave acquisition mode

1) Working mode:acquisition mode.

2) The host is a PC or touch screen connecting to a wireless transmission module (such as KYL-300I).

3) The host and  KYL-816 module use the standard Modbus RTU communication protocol.

4) The host and KYL-816 module should be with the same working channel

5) The ID of KYL-816 can be set from 1-254



80606.jpg

 

 

2、Transmission method for Point to Point

1)Working mode select the timing mode. One is master and the other is slave. Master regularly acquires input signals, encodes and wirelessly transmits.The receiver receives, decodes and outputs the corresponding voltage or current signal, ie, the output signal of the receiver module changes following the input signal of the transmitter.



80607.jpg


2) The timing transmission interval can be set from 30 milliseconds to 60 seconds. When set to 000, the KYL-816 acquisition module only acts as a receiving unit and does not transmit data. When the sending interval is set to non-zero, KYL-816 master sends the acquired data at set regular intervals. The transmission interval of minimum transmission unit is related to the wireless communication rate, which is generally 500ms. If a lower transmission interval is required, it should be specified before ordering.

3) When 2pcs KYL-816 modules communicate with each other, they must have the same ID and channel.

4) PIN3(ERR) and PIN4(ERR) of KYL-816 can be used as alarm output. When the receiver does not receive the transmitter's signal, it will output a "closed" signal.

5) When the communication fails, the output voltage or current can be automatically set to 0 or maintain the original output state. This function can be set in the "fault output mode" in option settings.

 

Parameter configuration

 

1、Parameter configuration

用戶可以通過配置軟件KYL-806對(duì)模塊進(jìn)行參數(shù)配置??刹僮鞯膮?shù)包括

1)模塊地址。范圍從001-254。

2)工作信道。共有1-16個(gè)信道,每個(gè)信道有不同的工作頻率。

3)工作模式。定時(shí)模式/采集模式。

4)主機(jī)/從機(jī)。定時(shí)模式下有效,主機(jī)按設(shè)定的間隔主動(dòng)發(fā)送數(shù)據(jù),從機(jī)接收數(shù)據(jù)并輸出模擬信號(hào)。

5)定時(shí)發(fā)送間隔。定時(shí)模式下KYL-806的發(fā)送間隔,10毫秒至60秒可設(shè)置。

6)故障輸出時(shí)間。定時(shí)模式下主從機(jī)通訊中斷持續(xù)的時(shí)間超過故障輸出時(shí)間時(shí),主/從機(jī)將輸出報(bào)警信號(hào),

     直到重新同步。

7)故障輸出模式。如果選擇“斷開”,定時(shí)模式下主從機(jī)通訊中斷持續(xù)的時(shí)間超過故障輸出時(shí)間時(shí),主/從機(jī)

     所有輸出將輸出0信號(hào),直到重新同步。

The user can configure parameters of the module by the software of KYL-806. Operable parameters include

1) Module ID. Range from 001-254.

2) Working channel. There are 1-16 channels with different frequency.

3) Working mode. Timing mode / acquisition mode.

4) Master/slave. Valid in timing mode, the host sends data actively at set interval, slave receives data and outputs analog signal.

5) Timed transmission interval. The transmission interval of KYL-806 in timing mode can be set from 10ms to 60 seconds.

6) Fault output time. When the master-slave communication interruption lasts longer than the fault output time in the timer mode, the master/slave will output an alarm signal.

      Until resynchronization.

7) Fault output mode. If “Off” is selected, the master/slave is interrupted when the master/slave communication interruption lasts longer than the fault output time in the timer mode.

      All outputs will output a 0 signal until resynchronization.



Pic: Parameter configuration software

80608.jpg

2、How to use software

1)使用編程線直接連接KYL-806到PC機(jī)。打開KYL-80X.EXE,選擇正確的端口。

2)上電,如果連接正常,KYL-RTU會(huì)顯示“連接成功”,先點(diǎn)擊“檢測(cè)”按鈕,此后用戶可根據(jù)需要修改模塊

參數(shù),或者進(jìn)行模擬量采集以及模擬量輸出控制的測(cè)試。

1) Use the programming line to connect KYL-806 directly to the PC. Open KYL-80X.EXE and select the correct port.

2) After power-on, if the connection is normal, KYL-RTU will display "Connected successfully", click the "Test" button first, after which the user can modify the module as needed

Parameters, or tests for analog and analog output control.



80609.jpg

 

KYL-816 Using Method 

 

 

1、Install the antenna to the module.

 

2. According to the use requirements, set the communication parameters with our company's standard programming cable, including the following contents:

 

1) Working mode. For point-to-point, please select the timing mode, Modbus master-slave networking, use the acquisition mode.

2) Working channel. The modules communicate with each other with the same working channel, 16 channels can be set.

3) Module ID. For point-to-point, the modules communicate should be with the same ID; in the acquisition mode, different modules must be set with different IDs.The master queries different modules based on the ID.

4) In the timing mode, set master/slave, timing interval, fault output time, and fault output mode.

 

3, Disconnect the programming cable, connect KYL-816 and the corresponding switch input, switch output device.

 

4, Connect the power (12-30V), open the power switch, output current of the power supply should be more than 500mA .

 

5. If KYL-816 works in acquisition mode, the user host needs to connect a wireless module (such as KYL-300I) and send acquisition command by the wireless module.In the acquisition mode, the user can also modify the KYL-816's parameters directly via wireless transmission command without programming cable.

 

6, Wireless remote acquisition, control testing.



 

*Remark:To avoid more than two remote control systems working at the same time in one remote control range, the module for different system should choose different channel (working frequency);

 

Outline drawing

 

              KYL-816 Outline drawing

80610.jpg

Packaging accessories

1、Standard accessories

1、1pc KYL-816 module。

        2、1pc antenna

        Pic.:Standard accessories 




80611.jpg

2、Selectable accessories

1、Selectable antenna。(Users can choose antenna if need)

        Pic.:Selectable accessories



80612.jpg






 

Previous: KYL-815-LORA